Job Menu
R-53
; Min Ground Clearance: When checked, a warning will occur if a
shot is taken at a location on the rod that is within this distance to
the ground.
; Max Loop Misclosure: When checked, the error computed after a
level loop is closed will be surrounded with exclamation points in the
Close Loop
screen and Level Notes screen if the error exceeds this
value.
; Upper-Lower Wire Reading <: When checked a warning will
occur if the difference between the upper stadia and crosshair exceeds
the difference between the crosshair and lower stadia by this value.
(This only applies to the Three Wire level method.)
Load FGCS Defaults : Opens the FGCS Defaults screen, described
below, where the default tolerances for a specified level loop order
and class can be loaded.